Ultraviolet astronomical spectrograph calibration with laser frequency combs from nanophotonic lithium niobate waveguides | Nature Communications
Nature Communications volume 15, Article number: 7614 (2024) Cite this article
1761 Accesses
1 Citations
1 Altmetric
Metrics details
Astronomical precision spectroscopy underpins searches for life beyond Earth, direct observation of the expanding Universe and constraining the potential variability of physical constants on cosmological scales. Laser frequency combs can provide the required accurate and precise calibration to the astronomical spectrographs. For cosmological studies, extending the calibration with such astrocombs to the ultraviolet spectral range is desirable, however, strong material dispersion and large spectral separation from the established infrared laser oscillators have made this challenging. Here, we demonstrate astronomical spectrograph calibration with an astrocomb in the ultraviolet spectral range below 400 nm. This is accomplished via chip-integrated highly nonlinear photonics in periodically-poled, nano-fabricated lithium niobate waveguides in conjunction with a robust infrared electro-optic comb generator, as well as a chip-integrated microresonator comb. These results demonstrate a viable route towards astronomical precision spectroscopy in the ultraviolet and could contribute to unlock the full potential of next-generation ground-based and future space-based instruments.
Precise astronomical spectroscopy has led to the Nobel-Prize-winning discovery of the first exo-planet via the radial velocity method1, which relies on the precise tracking of minute Doppler shifts in the stellar spectrum caused by an orbiting planet. The detection of Earth-like planets in the habitable zone around a Sun-like star requires measuring a radial velocity change as small as 10 cm/s (relative Doppler-frequency shift of 3 × 10−10) over the time scale of 1 year. This necessitates regular wavelength calibration of the spectrograph against a suitable calibration light source. Highly stable and accurate calibration light sources hence take on a key role in astronomical precision spectroscopy.
Calibration sources with outstanding accuracy and precision can be provided by laser frequency combs2,3 (LFCs). Their spectra are comprised of large sets of discrete laser lines whose frequencies can be precisely known when linked to a metrological frequency standard, on a level that exceeds the astronomical requirements. Provided their lines can be separated by the spectrograph, LFCs can serve as exquisite wavelength calibrators4,5 and are then also referred to as astrocombs (Fig. 1a). Recent years have seen significant progress in developing astrocombs6,7,8,9,10 and extending their coverage to visible (VIS) wavelengths, where the emission of Sun-like stars peaks, and to near-infrared wavelength, where relatively cold stars can accommodate rocky planets in tight orbits.
a Precision spectroscopy of astronomical objects enabled by laser frequency combs (LFC) providing absolutely and precisely known laser frequencies, cf. main text. QSO: quasi-stellar object, H, H2: hydrogen, D: deuterium, P: optical power. b Atmospheric transmission (high altitude, dry), spectral ranges for different astrophysical studies. c Expected redshift drift signal for the standard ΛCDM cosmology89 in units of cm/s per decade (Sandage test) as a function of wavelength, corresponding to the redshifted H I Lyα transition. d Concept of broadening and transferring a high-repetition-rate astrocomb from infrared (IR) to visible (VIS) and ultraviolet (UV) wavelengths based on optical χ(2)- and χ(3)-nonlinearities.
Extending astrocombs further towards the atmospheric cutoff and into the ultraviolet (UV) regime would not only be relevant to exo-planet science, but highly desirable for fundamental physics and precision cosmology (Fig. 1b). Indeed these are also major science drivers for the upcoming ANDES high-resolution spectrograph at the extremely large telescope (ELT)11. For instance, by accurately determining the wavelengths of narrow metal absorption features in the spectra of quasi-stellar objects (QSOs), one can infer the value of the fine-structure constant, α, at the place and time of absorption, i.e. billions of years ago. This allows us to test whether fundamental physical constants might have varied on cosmological scales12,13. Another exciting, but extremely demanding science case is the direct observation of cosmic expansion in real time, often referred to as the Sandage test14,15,16. This requires detecting a drift of H I Lyα forest absorption features in QSO spectra by just a few cm/s (relative frequency shift of 3 × 10−11) over several decades. As lined out in ref. 17, observations and corresponding wavelength calibrations in the UV are needed to access low redshifts, z, in particular, the important zero-crossing of the drift at z = 2, corresponding to 365 nm (Fig. 1c). Achieving such an extreme level of wavelength stability will require a community effort over the next decade to develop improved spectrographs, data analysis methods, and in particular LFC-based calibration sources18. Furthermore, it has recently become clear that a detailed modeling of the instrumental line-spread function is crucial to further improve the accuracy and stability of spectroscopic observations17,19,20. This, however, requires a broadband calibration source with a spectrum of narrow lines, such as those of an LFC.
Astrocombs can be derived from high-repetition-rate (frep > 10 GHz) laser sources, such as line-filtered mode-locked lasers6,7,8,21, electro-optic (EO) comb generators22,23 and chip-integrated microresonators24,25,26,27,28. Their spectra consist of equidistant optical laser frequencies νn = ν0 + nfrep, spaced by the laser’s pulse repetition rate frep and with an offset frequency ν0, which we here define to be the central frequency of the laser (n is an integer comb line index). To transfer the comb spectra to the desired wavelength range and to increase their spectral coverage, second- (χ(2)) and third-order (χ(3)) nonlinear optical effects are utilized. However, the high-repetition rates of >10 GHz, that are necessary for the comb lines to be separated by the spectrograph, imply low pulse energies and hamper nonlinear optical effects. In addition, and especially at shorter wavelengths, strong material dispersion complicates the efficient nonlinear energy transfer.
So far, short-wavelength blue and green astrocombs have been achieved via second-harmonic generation of infrared mode-locked lasers21,29,30 and of EO combs31 in bulk χ(2)-nonlinear crystals. Spectral broadening in χ(3)-nonlinear photonic crystal fiber resulted in astrocombs spanning from infrared (IR) to VIS wavelength32,33,34, some extending to below 450 nm. In addition to these approaches, micro- and nanophotonic waveguides made of highly nonlinear materials can further increase the efficiency in a compact setup. In the IR, χ(3)-nonlinear silicon nitride (Si3N4) waveguides have led to broadband astrocombs35, and via third-harmonic generation, a 10 GHz IR comb has been transferred to VIS wavelengths36. Strong nonlinear effects in waveguides, including harmonic frequency generation, may also be obtained via the quadratic χ(2)-nonlinearity. At low pulse repetition rates, spectra across multiple optical octaves have been obtained in large-mode area (~100 μm2) periodically poled lithium niobate (LiNbO3) waveguides with mm-long propagation distances37,38,39,40. Notably, periodically poled LiNbO3 waveguides were utilized with a 30 GHz repetition rate line-filtered erbium-doped mode-locked laser41, creating harmonic spectra in VIS and UV domains for astronomical spectrograph calibration. In addition, recent work leveraged a combination of second-harmonic and sum-frequency generation based on a titanium-doped sapphire laser to obtain, in conjunction with line-filtering, a continuous green to ultraviolet 30 GHz astrocomb42. In nanophotonic waveguides from thin-film LiNbO343,44,45,46,47,48, owing to their sub-μm2 modal confinement, highly-efficient UV spectral generation has been reported49,50,50,51,52,53,54,55,56,57,58,59, including at 10 GHz repetition rate59. However, astronomical spectrograph calibration in the UV spectral range has so far not been demonstrated.
Here, we demonstrate astronomical spectrograph calibration with laser frequency combs in the UV below 400 nm. Specifically, we design chip-integrated nano-structured LiNbO3 waveguides with sub-μm2 mode cross-section and a tailored poling pattern to enable efficient UV astrocomb generation via cascaded harmonic generation from a robust telecommunication-wavelength 18 GHz EO comb, as well as, a 25 GHz chip-based microresonator comb. The generated astrocombs are tested in March 2023 on the high-resolution echelle spectrograph SOPHIE60 at the Observatoire de Haute Provence (OHP, France), achieving radial-velocity precision in the range of 1 to 2 m/s.
We base our astrocombs on a robust, telecommunication-grade EO comb with a pulse repetition rate of 18 GHz, as well as, a microresonator comb with a repetition rate of 25 GHz. Both are derived from an IR continuous-wave (CW) laser of frequency ν0≈192 THz (wavelength ca. 1.56 μm) and operate intrinsically at a high-repetition rate, so that filtering of unwanted comb lines is not required. To transfer the IR comb to the UV (and VIS), we utilize chip-based LiNbO3 nanophotonic waveguides, for cascaded harmonic generation as illustrated in Fig. 1d. The possible comb frequencies are
where m is the harmonic order. In general, each harmonic m of the comb spectrum has a different offset frequency mν0. While this can facilitate the detection of the comb’s offset frequency51,55,57,59, care must be taken to avoid inconsistent frequency combs from overlapping harmonics with different offsets. Alternatively, stabilizing ν0 to a multiple of frep could address this point. Practically, this could be achieved, for instance, by locking the beatnote between adjacent harmonics to zero61, or via an auxiliary low-repetition rate frequency comb62.
A key difference between broadband electro-optic combs obtained via conventional self-phase modulation χ(3)-based supercontinua and spectra generated via χ(2)-based harmonics, lies in the phase noise properties of their comb lines. In χ(3)-based spectra, the phase noise, impacting linewidth and line contrast, grows quadratically with the frequency distance from the fundamental pump laser. In contrast, in χ(2)-based harmonic spectra the phase noise (approximately) depends on the frequency distance from its corresponding harmonic’s center frequency (Supplementary Information SI, Section 1 and Supplementary Fig. 1). This property, along with the efficiency of the nanophotonic waveguides, permits us to directly generate comb lines in the ultraviolet from a telecom-wavelength electro-optic source, within a certain bandwidth around the harmonic’s center frequency; future extension of this bandwidth will, as we discuss in detail in the Section 1 in the SI and show in the Supplementary Figs. 2,3, require the addition of a noise filtering cavity, which has been established for broadband χ(3)-based electro-optic combs63, but is not implemented in this initial proof-of-concept demonstration.
An illustration of a nano-structured LiNbO3 waveguide and the strong mode confinement to sub-μm2 cross-section for efficient nonlinear conversion is shown in Fig. 2a. The waveguides are fabricated from a commercially available undoped lithium niobate-on-insulator (LNOI) substrate with an 800-nm-thick LiNbO3 layer via electron-beam lithography and reactive-ion etching, resulting in a sidewall angle of ~75° (Fig. 2c, Methods, SI Section 2 and Supplementary Figs. 4, 5). The waveguides taper to a width of 2500 nm at the chip facet, for input and output coupling. In the first design step, considering the fundamental transverse electric field polarization (TE) waveguide mode, we define the waveguide geometry, which in nanophotonic waveguides enables engineering of the waveguide’s group velocity dispersion (GVD), and additional χ(3)-nonlinear spectral broadening of the input IR comb. In unpoled waveguides, top widths in the range of 800 to 1200 nm result in anomalous GVD and the most significant broadening. Spectral broadening is also possible in the normal GVD regime, typically resulting in less broad, but more uniform spectra.
a Geometry of a nanophotonic lithium niobate (LiNbO3) waveguide, showing the optical mode profile for the fundamental transverse electric field polarization (TE) mode and a possible poling pattern with spatially variable poling period Λ. The extraordinary crystal axis is oriented along the x-direction to access the highest electro-optic tensor element of LiNbO3. b Poling periods Λ required for quasi-phase-matching of various nonlinear optical processes for waveguides of different (top) width as a function of the fundamental comb’s wavelength. SHG: second-harmonic generation, SHG+F: sum-frequency generation of second-harmonic and fundamental comb, THG+F: sum-frequency generation of third-harmonic and fundamental comb, SHG+SHG: sum-frequency generation of the second-harmonic. Respective higher-order phase matching with three-fold period Λ is indicated (the current fabrication limit only allows for Λ > 2 μm). c Photograph of a waveguide in operation and scanning electron microscope image of the LiNbO3 on silica (SiO2). d–g Examples of waveguide designs showing poling pattern (top), experimentally generated spectra for different input pulse energies provided by a 100 MHz, 80 fs mode-locked laser with a central wavelength of 1560 nm (waveguide cross-section are shown as insets and on chip-pulse energy is indicated by the color code) and pyChi64 simulation results (bottom) for a pulse energy of 50 pJ. The spurious spikes observed in the traces for 4 pJ pulse energy are manifestations of the noise floor of the optical spectrum analyzer (Yokogawa AQ6374).
In a second design step, we define the waveguide’s poling pattern to transfer the broadened fundamental spectrum to shorter wavelengths. This can be achieved efficiently, when a fixed phase relation between the involved waves is maintained (phase matching). However, due to chromatic material dispersion, this cannot easily be fulfilled across the entire spectral interval of interest (regardless of the choice of waveguide geometry and GVD at the fundamental wavelength). As an alternative to natural phase matching, in ferroelectric crystals such as LiNbO3, quasi-phase matching (QPM) is possible. Here, the sign of the χ(2)-nonlinearity is periodically flipped within segments of length Λ (poling period), via poling of the crystal’s domains (Methods) to compensate the increasing phase-mismatch between the waves. For sum-frequency generation processes (which underlie harmonic generation), Λ is
where k1 and k2 are the input propagation constants, and k3 is the output propagation constant in the waveguide. To achieve broadband QPM, Λ may be chirped (i.e., varied along the waveguide). To design Λ(z) (z is the spatial coordinate in the propagation direction), we numerically compute the frequency ω dependent propagation constants k(ω) of the fundamental waveguide mode for waveguide top widths of 800, 1000, and 1200 nm. Based on Eq. (2), we derive the required poling period Λ for a number of sum-frequency processes that would result in second-harmonic generation (SHG = fundamental + fundamental), third-harmonic generation (THG = SHG + fundamental), and fourth-harmonic generation (FHG = SHG + SHG or THG + fundamental). These periods Λ are shown in Fig. 2b, as a function of the fundamental comb’s wavelengths.
Prior to astrocomb generation, we tested different waveguide designs with a low-repetition rate (100 MHz), 80 fs mode-locked laser operating at a center wavelength of 1560 nm. The pulses are coupled to the chip via a high-numerical aperture lens (NA = 0.7) lens and the spectra are collected using reflective collimation optics and a fluoride multimode fiber that connects to a grating-based optical spectrum analyzer (Yokogawa AQ6374). Utilizing a lensed fiber with a calibrated coupling efficiency as a temporary output coupler, we determine the input coupling efficiency of the high-NA lens to be 13 ± 2%. To illustrate the impact of the poling structure, we compare in Fig. 2d a waveguide poled for broadband SHG (Λ weakly chirped as indicated) with an unpoled waveguide (Fig. 2e), demonstrating markedly different behaviors. The poled waveguide creates a broadband SHG at ~400 THz, whereas the unpoled waveguide only creates a narrow SHG. These observations agree with numerical simulation via pyChi64 (shown below the experimental spectra). Note that the poled waveguide also exhibits a more substantial broadening of the input spectrum (and its harmonics), which can be explained through the contributions of cascaded χ(2)-processes to the effective χ(3)-nonlinearity. In a more advanced design (Fig. 2f) a short SHG section (supporting also broadening) is followed by a longer and strongly chirped section designed to enable FHG. Indeed, pronounced FHG is visible, although, in contrast to the simulation, it is not stronger than the THG signal. We attribute this to the very small values of Λ < 2 μm, which are challenging to fabricate with high fidelity. To overcome the fabrication challenge for very small Λ, we also consider higher-order QPM (Fig. 2b). In higher-order QPM, the poling period is an integer multiple q of the fundamental poling period Λ65, which relaxes fabrication requirements at the cost of reduced efficiency. In our design for symmetric poling (equal length for both crystal orientations), q is an odd-integer (here: q = 3). In addition, unintentional phase-matching may occur involving higher-order waveguide modes and coupling between orthogonal polarizations. A possible design is shown in Fig. 2g, where, after a short length of SHG poling, Λ ranges from 2 to 7 μm. This choice of Λ respects the fabrication limit and provides QPM for most processes (Fig. 2b). The generated harmonic spectrum extends across 600 THz (ca. 350 to 1000 nm) within ~20 dB of dynamic range, demonstrating, in agreement with previous work59, the potential of LiNbO3 waveguides for generating gap-free spectra in the VIS and UV domains.
With the principle of efficient harmonic generation validated, we build a dedicated ultraviolet astrocomb and use it for spectrograph calibration under realistic conditions at the high-resolution echelle spectrograph SOPHIE60 at the Observatoire de Haute Provence (OHP, France). With the help of an Echelle-grating and a prism, the spectrograph cross disperses the input spectrum on a two-dimensional charged coupled device (CCD) detector array so that the spectrum is arranged in a vertically separated set of nearly horizontal lines (Echelle orders), where each line represents a distinct wavelength interval. The SOPHIE spectrograph, covers the wavelengths λ from 387 to 708 nm with a resolving power of \(R=\frac{\lambda }{\Delta \lambda }\approx 75^{\prime} 000\) (i.e., frequency resolution of approximately 10 GHz at 400 nm wavelength) and its echelle-grating is enclosed in a pressure vessel to reduce externally induced drifts. Traditionally, wavelength calibration can be obtained via thorium-argon hollow-cathode lamps (ThAr) and a passively-stabilized Fabry-Pérot etalon (FP)66,67, permitting calibration on the 1 to 2 m s−1 level68.
As an initial IR comb generator, we utilize an 18 GHz EO comb, similar to ref. 62 (Fig. 3a). A CW laser of wavelength 1556.2 nm is stabilized to an optical resonance frequency in rubidium (Rb), providing an absolute frequency anchor for the IR EO comb (Methods). Comb generation proceeds by sending the CW laser through two electro-optic phase- and one electro-optic intensity modulator, creating an initial IR comb spanning ~0.6 THz. The modulation frequency of 18 GHz is provided by a low-noise microwave synthesizer, referenced to a miniature Rb atomic frequency source; over the relevant time scales of our experiments, a relative frequency stability better than 10−11 is achieved (Methods). In a waveshaper, a polynomial spectral phase up to third order is imprinted on the EO comb spectrum, to ensure short pulses after the amplification in an erbium-doped fiber amplifier (EDFA) and an additional stretch of optical fiber for nonlinear pulse compression. In this way, an 18 GHz femtosecond pulse train with 3 W of average power can be generated. The pulses are out-coupled to free space and coupled to the chip via a high-numerical aperture (NA = 0.7) lens (estimated on-chip-pulse energy ~20 pJ). Despite the high average input power levels, we did not observe any waveguide damage.
a Setup for ultraviolet (UV) astrocomb generation. Rb rubidium-based atomic references (main text, Methods); CW continuous-wave laser, PM phase modulator, IM intensity modulator, WS waveshaper, EDFA erbium-doped fiber amplifier, Col. fiber-to-free-space collimator, M mirror, CU calibration unit splitting the comb equally into A and B fibers, CCD SOPHIE charged coupled device detector. All fibers following the lithium niobate chip and feeding the spectrograph are multimode fibers. b Composite CCD detector image, obtained with two different settings of the flux-balancing prism, showing fourth- and third-harmonic in the UV and visible (VIS) wavelength ranges. The inset indicates how wavelengths increase along the individual cross-dispersed echelle orders. The magnified CCD sub-images show the distinguishable but slightly overlapping frequency comb lines on the detector, originating from the two spectrograph fibers, which are both fed by the same comb. c Extracted 1-dimensional comb spectra of both harmonics; the insets show a magnified (linear scale) portion of the spectrum and the 18 GHz-spaced comb lines. The UV detector cutoff is marked.
For comb generation, we choose the waveguide in Fig. 2f, as it exhibits a strong UV signal and a clear separation between the harmonics. We arrange the waveshaper and the optical fiber after the amplifier such that the driving pulses are of ca. 200 fs duration, maintaining the separation between the harmonics, so that the emergence of inconsistent frequency combs, as described above, can be excluded. As we show in the SI, Section 3 and Supplementary Fig. 6, shorter pulses can enable the generation of broadband and merging harmonics, which opens opportunities for future work. The generated spectra are similar to those generated at a lower repetition rate (Fig. 2d–g). The chip’s output, including fundamental and higher-order waveguide modes, is collimated using a parabolic mirror and sent through a tunable prism for coarse wavelength filtering and balancing of flux levels as needed, before being coupled to a multimode fiber. The light is sent through a mode-scrambler (Methods) and then routed to an auxiliary input port in the spectrograph’s calibration unit, which marks the interface between our LFC setup and the existing telescope and spectrograph infrastructure at OHP60. The calibration unit splits the comb light equally into two optical fibers (A/B fiber), which are placed next to each other on the spectrograph entrance slit, each creating an equivalent cross-dispersed spectrum on the two-dimensional detector. Figure 3b shows a comb spectrum as recorded on the CCD detector of the SOPHIE spectrograph. The comb structure of the LFC spectrum is clearly visible along the individual spectral orders of the cross-dispersed echelle spectrograph for both A and B fibers. Data extraction and reduction of the LFC exposures is performed using a custom code initially developed for the ESPRESSO spectrograph69. It extracts the spectral information from the two-dimensional detector frame using a variant of the flat-relative optimal extraction algorithm70, provides default wavelength calibration based on a combined ThAr/FP wavelength solution69,71, and combines the data from the individual spectral orders to a single one-dimensional spectrum (Fig. 3c) and thus makes it accessible to subsequent analysis. The resolving power of the spectrograph is not sufficient to fully separate the comb lines. In particular, in the UV part of the spectrum, the wings of the spectrograph’s line-spread functions for adjacent comb lines overlap and imply a reduced contrast. Nevertheless, the individual comb lines are clearly discernible.
To test the stability of the LFC-based wavelength calibration, we obtained over several hours repeated LFC exposures interleaved with exposures of the FP etalon. The two types of exposures allow us to measure the spectrograph drift in independent ways, once relative to the LFC and once relative to the FP. After data reduction as described above, all LFC lines in the spectra are fitted individually to determine their positions on the detector (Methods). For the FP exposures, the gradient method72 is used to non-parametrically detect shifts of the spectra on the detector. As shown in Fig. 4a, we obtain separate drift measurements from the third- and fourth-harmonic and, in addition, one drift value from the FP, where we only use the FP lines that overlap spectrally with the third-harmonic (the FP calibration does not cover the UV). All three measurements agree well (within the amplitude of their scatter) and detect a systematic spectrograph drift of ca. −2 m/s over 4 h. The agreement between the third-harmonic and the FP validates the LFC, and the agreement between the fourth-harmonic with the two other measurements extends the validation to the UV regime. The slightly higher noise in the LFC data, i.e., remaining differences between third- and fourth-harmonic and scatter around the global trend, compared to the FP drift measurement, can probably be attributed to a combination of effects, e.g., intrinsic systematics of the spectrograph like detector stitching issues73 or charge transfer inefficiency (CTI)74 combined with a change in the flux levels of the LFC lines. Moreover, the line spacing of our comb (18 GHz), which is limited by our specific technical components, is less than half the FSR of the FP calibrator (39 GHz). As a result, comb line fitting (Methods) is more challenging, and a slightly higher scatter can be expected, when compared to the FP-based calibration. Implementing a comb with larger spacing or higher resolution spectrographs can address this challenge. The fact that, nevertheless, the scatter in the FP and comb-based calibrations are comparable, indicates that the obtained precision is here limited by the spectrograph, not by the comb (indeed, the scatter is consistent with the design goals of the spectrograph60).
a Spectrograph drift measurement based on the Fabry-Pérot (FP) etalon in the visible (VIS) wavelength and the laser frequency comb (LFC) in VIS and ultraviolet (UV) wavelength range. The FP calibration data has been restricted to its spectral overlap with the VIS LFC; Error bars indicate formal uncertainties based on propagation of photon- and read-out noise. b Absolute spectroscopy of thorium emission lines by the LFC-calibrated spectrograph. The deviation of the literature values from our LFC-calibrated measurement is shown as a function of wavelength and separately for A and B fiber. Error bars indicate formal fitting uncertainties based on a propagation of photon- and read-out noise; dashed lines indicate 16th, 50th, and 84th percentiles. Right panel: histogram of the deviations, separated for Fiber A and B. Mean and standard deviation are indicated.
To test the accuracy of our LFC-based calibration, we compare it to the established laboratory wavelengths of the ThAr hollow-cathode lamp. For this, two exposures, one containing the LFC and the other the ThAr spectrum, are obtained in quick succession, which ensures that no relevant spectrograph drift happens between the two exposures. In the extracted LFC spectrum, individual lines are fitted (see above and Methods) and, together with the knowledge about their true, intrinsic frequencies (Eq. (1)), a purely LFC-based wavelength solution, i.e., a relation between CCD pixel position and wavelength, is derived for the spectral region covered by the comb. This LFC wavelength solution is then applied to the extracted ThAr spectrum and, after fitting of line centroids, LFC-calibrated wavelengths are assigned to the thorium lines. These are then compared to the laboratory wavelengths75 and the deviations are shown in Fig. 4b. The histogram of all deviations shows a global offset of −9 to −14 m/s with a standard deviation of >20 m/s, which is consistent with zero offset, and also with an equivalent comparison performed with the highly accurate ESPRESSO spectrograph69. We note that the large uncertainty (the standard deviation in the histogram) is not limited by the comb calibrator but due to the low number of only ~100 ThAr lines that are available for comparison. The scatter of individual line deviations (and the difference between Fibers A and B), which significantly exceeds the formal uncertainties, has also been observed for other spectrographs (e.g., ESPRESSO69) and seems to be a common systematic, probably related to an imperfect determination of the instrumental line-spread function. We confirm that this scatter is identical when comparing thorium lines to LFC or ThAr/FP wavelength solutions69,71. Therefore, we conclude that the LFC wavelength calibration is accurate to the level testable with SOPHIE. Both measurements combined validate on the proof-of-concept level that the generated astrocomb can provide precise and absolute calibration even at UV wavelengths.
Finally, we explore photonic chip-integrated microresonators (microcombs24,25,26) as the fundamental IR comb generator. While their current level of maturity is lower than that of EO comb generators or mode-locked lasers, microcombs can provide compact and energy efficient76 high-repetition rate, low-noise femtosecond pulses77, and their potential for microresonator astrocombs has already been demonstrated in the IR spectral range27,28. Combined with highly-efficient frequency conversion in LiNbO3 waveguides, potentially in a resonant configuration78,79,80, they could open new opportunities for space-based calibrators, where energy consumption, size, and robust integration are key. Such space-based systems could calibrate ground-based observatories through the atmosphere, or provide calibration to space-based observatories, which would entirely avoid limiting atmospheric effects, such as absorption or turbulence. Therefore, as a proof-of-concept, we replace the electro-optic comb generator with a silicon nitride microresonator81,82 (Fig. 5c, photo) operating at frep = 25 GHz (Methods). A portion of the generated comb spectrum is bandpass-filtered and pre-amplified in an erbium-doped fiber amplifier (Fig. 5a). Figure 5b shows the IR comb spectrum generated by the microresonator as well as the filtered and amplified spectrum. The remainder of the setup is the same as described before for the EO astrocomb (Fig. 3a). While we do not stabilize the microcomb spectra, we observe broadband harmonics of distinct comb lines, similar to the EO comb configuration (Fig. 5c), illustrating the potential of implementing all nonlinear optical components via highly-efficient photonic integrated circuits.
a Modified setup for microresonator-based ultraviolet (UV) astrocomb generation. b Microresonator comb output spectrum (gray); bandpass-filtered and pre-amplified microresonator-based comb spectrum. c Microresonator-based UV fourth-harmonic and visible (VIS) third-harmonic comb spectra, following the scheme in Fig. 3. The photo shows the photonic chip with the microresonator (dashed-line box) and the inset shows a scanning electron microscope image of the Si3N4 resonator waveguide.
Although lithium niobate is known to show photo-induced damage by visible and ultraviolet light, we did not observe any signs of degradation in our experiments and attribute this to the relatively low flux levels in these wavelength domains (The power in the harmonics and corresponding conversion efficiencies are presented in the SI, Section 4 and Supplementary Fig. 7). In a dedicated experiment, described in Section 5 of the SI and Supplementary Fig. 8, we transmitted light of a 405 nm laser diode through the waveguide and did also not observe any degradation. Zirconium-doping of the lithium niobate can further increase the damage threshold for visible and ultraviolet light83.
In this work, we demonstrate astronomical spectrograph calibration in the UV wavelength range with a laser frequency comb. This demonstration is particularly relevant to the emerging field of optical precision cosmology with next-generation instruments and telescopes. Our astrocomb’s architecture is based on periodically poled lithium niobate nanophotonic waveguides tailored to provide efficient frequency conversion of a robust, alignment-free 18 GHz electro-optic frequency comb. Moreover, we show the compatibility of the approach with photonic chip-integrated microcombs, creating opportunities for future space-based systems. This nonlinear transfer of a microcomb to VIS and UV wavelengths also adds new operating domains to the repertoire of these sources. The approach demonstrated here can be utilized to extend calibration beyond established wavelength ranges towards shorter wavelengths. Future work may pursue wider harmonic spectra (SI, Section 5), where however, consistency of the generated spectra via suitable control of the fundamental comb’s offset-frequency (as described above) and noise suppression as previously demonstrated for electro-optic combs63 would need to be implemented. With improved coupling to the waveguide47,84 this could enable gap-free VIS and UV operation based on robust telecommunication-wavelength IR lasers. Similar results may be possible also in other waveguide materials such as aluminum nitride (AlN), where broadband phase matching may be achieved through chirped geometries85. In addition to the development of the comb source itself, spectral flattening86 will be needed to ensure optimal exposure of the CCD and to avoid systematic effects that can arise from strong modulation of the comb's spectral envelope. In sum, the demonstrated approach opens a viable route towards astronomical precision spectroscopy in the ultraviolet based on robust infrared lasers and may eventually contribute to major scientific discoveries in cosmology and astronomy.
Lithium niobate waveguides for UV comb generation are fabricated from an 800-nm-thick x-cut LiNbO3 layer on 3 μm SiO2 and bulk Si substrate (NANOLN). First, chromium (Cr) electrodes for periodic poling are fabricated using electron-beam lithography and lift-off. Ferroelectric domain inversion is performed by applying a high-voltage waveform across the electrodes, adapted from ref. 87 (SI, Fig. 5). After poling, the electrodes are removed via chemical etching. Waveguides are patterned using electron-beam lithography on a Cr hard mask. Cr is etched using argon (Ar) ion-beam etching and subsequently, the lithium niobate layer is fully etched (no slab remaining) via reactive-ion etching with fluorine chemistry. The remaining Cr hard mask is later removed with chemical etching. Lastly, a 3-μm-thick SiO2 cladding layer is deposited using chemical vapor deposition and waveguide facets are defined by deep etching to ensure low-loss coupling to the waveguides. More details regarding the fabrication of lithium niobate waveguides can be found in SI, Section 2.
The Si3N4 microresonator is designed with a finger shape82 and fabricated via the subtractive processing method as described in ref. 81. The height and the width of the SiN waveguide are 740 nm and 1800 nm respectively, which result in a group velocity dispersion coefficient of β2 = –73 ps2/km for the fundamental TE mode at the pump wavelength. The total linewidth of the critically coupled resonator is 25 MHz. Lensed fibers are used for coupling into and out of the bus waveguide. More details are provided in Section 2 of the SI, including Supplementary Figs. 4,5.
A narrow-linewidth CW laser at telecommunication-wavelength 1556.2 nm (Redfern Integrated Optics, RIO Planex) is split and one part is used for EO comb generation. The other part is frequency-doubled and brought into resonance with the 5S1/2(Fg = 3) − 5D5/2(Fe = 5) two-photon transition in 85Rb atoms in a microfabricated atomic vapor cell, similar to ref. 88. A stable frequency lock of the CW laser to the two-photon transition is achieved by means of synchronous detection and by modulating the laser’s injection current. Using the same vapor cell and a laser with higher phase noise, we measured the fractional frequency instability of our system to an Allan deviation better than 2 × 10−12 for averaging times from 1 to 104 s.
The 10 MHz sine wave output of a commercial miniature atomic frequency source is provided to the microwave synthesizer as a stable reference. The miniature atomic clock we use is based on a transition in the ground state of 85Rb. Its relative frequency stability is specified by the manufacturer to be better than 1 × 10−10 (1 × 10−11) at 1 s (100 s) averaging time; daily drift <1 × 10−11.
The mode-scrambler suppresses detrimental laser speckles on the CCD (modal noise) that would result from the coherent LFC illumination after propagating through the multimode fiber train of the SOPHIE spectrograph. It consists of a rotating diffuser disc and has a throughput of ca. 5% effectively washing out any laser speckle pattern. Averaged over one CCD exposure time, it populates all fiber modes and, therefore, ensures a speckle-free image of the spectrographs’s entrance aperture on the CCD. After the mode-scrambler, the light is guided by a multimode fiber to the calibration unit. The calibration unit selects one of the installed calibration light sources or, via a temporarily added additional input port, the light from the LFC. The selected light is then sent to the spectrograph’s front-end, mounted at the Cassegrain focus of the OHP 1.93 m telescope, where it is simultaneously injected into A and B fibers feeding the spectrograph60.
The LFC lines are fitted to find their exact center positions. Due to the limited resolution of the spectrograph, the comb lines are not fully separated but partially overlap, particularly in the UV domain. Therefore, always three LFC lines are fitted together, a central line of interest and two flanking ones to model the flux contributed by their wings. In addition, the diffuse background flux is locally modeled by a polynomial of first order. A detailed characterization of the SOPHIE instrumental line-spread function is not available. Therefore, we have to resort to model all lines with a simple Gaussian shape. In addition, due to the limited sampling (about 2.5 pixels per FWHM) on the detector, a simultaneous and unconstrained fit of all nine model parameters (positions and amplitudes of the three lines in question, one common linewidth, and amplitude and slope for the diffuse background) leads to degeneracies and unphysical fit results. The width of all LFC lines in the fit is, therefore, fixed to an FWHM of 2.47 pixels. This value was inferred from the thorium lines and, although not capturing the variation of the instrumental line-spread function along individual spectral orders or with wavelength in general, was found to better describe the line shapes than a width that is fixed in velocity units.
For each exposure, the fitted line centroids are compared to the corresponding positions in the first exposure of the sequence, the differences converted to radial velocity shifts following the Doppler formula, and then combined to provide one average drift measurement per exposure.
The data shown in the plots have been deposited in the Zenodo database https://zenodo.org/records/12607045; https://doi.org/10.5281/zenodo.12607045.
The numeric simulations in the current study used an open-source code available at https://github.com/pychi-code/pychi.
Mayor, M. & Queloz, D. A Jupiter-mass companion to a solar-type star. Nature 378, 355–359 (1995).
Article ADS Google Scholar
Fortier, T. & Baumann, E. 20 years of developments in optical frequency comb technology and applications. Commun. Phys. 2, 1–16 (2019).
Article Google Scholar
Diddams, S. A., Vahala, K. & Udem, T. Optical frequency combs: coherently uniting the electromagnetic spectrum. Science 369, eaay3676 (2020).
Article CAS PubMed Google Scholar
Murphy, M. T. et al. High-precision wavelength calibration of astronomical spectrographs with laser frequency combs. Mon. Not. R Astron. Soc. 380, 839–847 (2007).
Article ADS Google Scholar
Fischer, D. A. et al. State of the field: extreme precision radial velocities*. Publ. Astron. Soc. Pac. 128, 066001 (2016).
Article ADS Google Scholar
Steinmetz, T. et al. Laser frequency combs for astronomical observations. Science 321, 1335–1337 (2008).
Article ADS CAS PubMed Google Scholar
Li, Chih-Hao et al. A laser frequency comb that enables radial velocity measurements with a precision of 1 cm s-1. Nature 452, 610–612 (2008).
Article ADS CAS PubMed Google Scholar
Braje, D. A., Kirchner, M. S., Osterman, S., Fortier, T. & Diddams, S. A. Astronomical spectrograph calibration with broad-spectrum frequency combs. Eur. Phys. J. D 48, 57–66 (2008).
Article ADS CAS Google Scholar
McCracken, R. A., Charsley, J. M. & Reid, D. T. A decade of astrocombs: recent advances in frequency combs for astronomy [Invited]. Opt. Express 25, 15058–15078 (2017).
Article ADS PubMed Google Scholar
Herr, T. & McCracken, R. A. Astrocombs: recent advances. IEEE Photon. Technol. Lett. 31, 1890–1893 (2019).
Article ADS CAS Google Scholar
Marconi, A. et al. ANDES, the high resolution spectrograph for the ELT: science case, baseline design and path to construction. In Ground-Based and Airborne Instrumentation for Astronomy IX 720–735. (SPIE, 2022).
Webb, J. K., Flambaum, V. V., Churchill, C. W., Drinkwater, M. J. & Barrow, J. D. Search for time variation of the fine structure constant. Phys. Rev. Lett. 82, 884–887 (1999).
Article ADS CAS Google Scholar
Murphy, M. T. et al. Fundamental physics with ESPRESSO: precise limit on variations in the fine-structure constant towards the bright quasar HE 0515-4414. Astron. Astrophys. 658, A123 (2022).
Article CAS Google Scholar
Sandage, A., Véron, P. & Wyndham, J. D. Optical identification of new quasi-stellar radio sources. Astrophys. J. 142, 1307–1311 (1965).
Article ADS Google Scholar
Liske, J. et al. Cosmic dynamics in the era of extremely large telescopes. Mon. Not. R. Astron. Soc. 386, 1192–1218 (2008).
Article ADS CAS Google Scholar
Cristiani, S. et al. Spectroscopy of QUBRICS quasar candidates: 1672 new redshifts and a golden sample for the Sandage test of the redshift drift. Mon. Not. R. Astron. Soc. 522, 2019–2028 (2023).
Article ADS Google Scholar
Martins, C. et al. Cosmology and fundamental physics with the ELT-ANDES spectrograph. Exp. Astron. 57, 5 (2024).
Jovanovic, N. et al. 2023 Astrophotonics roadmap: pathways to realizing multi-functional integrated astrophotonic instruments. J. Phys. Photon. 5, 042501 (2023).
Article Google Scholar
Hirano, T. et al. Precision radial velocity measurements by the forward-modeling technique in the near-infrared. Publ. Astron. Soc. Jpn. 72, 93 (2020).
Article ADS Google Scholar
Milaković, D. & Jethwa, P. A new method for instrumental profile reconstruction of high-resolution spectrographs. A&A. 684, A38 (2024).
Benedick, A. J. et al. Visible wavelength astro-comb. Opt. Express 18, 19175–19184 (2010).
Article ADS PubMed Google Scholar
Kashiwagi, K. et al. Direct generation of 12.5-GHz-spaced optical frequency comb with ultrabroad coverage in near-infrared region by cascaded fiber configuration. Opt. Express 24, 8120–8131 (2016).
Article ADS CAS PubMed Google Scholar
Yi, X. et al. Demonstration of a near-IR line-referenced electro-optical laser frequency comb for precision radial velocity measurements in astronomy. Nat. Commun. 7, 10436 (2016).
Article ADS CAS PubMed PubMed Central Google Scholar
Kippenberg, T. J., Gaeta, A. L., Lipson, M. & Gorodetsky, M. L. Dissipative Kerr solitons in optical microresonators. Science 361, eaan8083 (2018).
Article PubMed Google Scholar
Pasquazi, A. et al. Micro-combs: a novel generation of optical sources. Phys. Rep. 729, 1–81 (2018).
Article ADS MathSciNet CAS Google Scholar
Gaeta, A. L., Lipson, M. & Kippenberg, T. J. Photonic-chip-based frequency combs. Nat. Photon. 13, 158–169 (2019).
Article ADS CAS Google Scholar
Suh, Myoung-Gyun et al. Searching for exoplanets using a microresonator astrocomb. Nat. Photon. 13, 25 (2019).
Article ADS CAS Google Scholar
Obrzud, E. et al. A microphotonic astrocomb. Nat. Photon. 13, 31 (2019).
Article ADS CAS Google Scholar
Wilken, T. et al. A spectrograph for exoplanet observations calibrated at the centimetre-per-second level. Nature 485, 611–614 (2012).
Article ADS CAS PubMed Google Scholar
Phillips, D. F. et al. Calibration of an astrophysical spectrograph below 1 m/s using a laser frequency comb. Opt. Express 20, 13711–13726 (2012).
Article ADS PubMed Google Scholar
Metcalf, A. J., Fredrick, C. D., Terrien, R. C., Papp, S. B. & Diddams, S. A. 30 GHz electro-optic frequency comb spanning 300 THz in the near infrared and visible. Opt. Lett. 44, 2673–2676 (2019).
Article ADS CAS Google Scholar
Glenday, A. G. et al. Operation of a broadband visible-wavelength astro-comb with a high-resolution astrophysical spectrograph. Optica 2, 250–254 (2015).
Article ADS Google Scholar
McCracken, R. A. et al. Wavelength calibration of a high resolution spectrograph with a partially stabilized 15-GHz astrocomb from 550 to 890 nm. Opt. Express 25, 6450–6460 (2017).
Article ADS CAS PubMed Google Scholar
Wu, Y. et al. 20 GHz astronomical laser frequency comb with super-broadband spectral coverage. In Ground-Based and Airborne Instrumentation for Astronomy IX 544–551. (SPIE, 2022).
Metcalf, A. J. et al. Stellar spectroscopy in the near-infrared with a laser frequency comb. Optica 6, 233–239 (2019).
Article ADS CAS Google Scholar
Obrzud, E. et al. Visible blue-to-red 10 GHz frequency comb via on-chip triple-sum-frequency generation. Opt. Lett. 44, 5290–5293 (2019).
Article ADS CAS PubMed Google Scholar
Phillips, C. R. et al. Supercontinuum generation in quasi-phase-matched LiNbO3 waveguide pumped by a Tm-doped fiber laser system. Opt. Lett. 36, 3912–3914 (2011).
Article ADS CAS PubMed Google Scholar
Iwakuni, K. et al. Generation of a frequency comb spanning more than 3.6 octaves from ultraviolet to mid infrared. Opt. Lett. 41, 3980–3983 (2016).
Article ADS CAS PubMed Google Scholar
Hickstein, D. D. et al. High-harmonic generation in periodically poled waveguides. Optica 4, 1538–1544 (2017).
Article ADS Google Scholar
Rutledge, J. et al. Broadband ultraviolet-visible frequency combs from cascaded high-harmonic generation in quasi-phase-matched waveguides. J. Opt. Soc. Am. B 38, 2252–2260 (2021).
Article ADS Google Scholar
Nakamura, K., Kashiwagi, K., Okubo, S. & Inaba, H. Erbium-doped-fiber-based broad visible range frequency comb with a 30 GHz mode spacing for astronomical applications. Opt. Express 31, 20274–20285 (2023).
Article ADS CAS PubMed Google Scholar
Cheng, YukShan et al. Continuous ultraviolet to blue-green astrocomb. Nat. Commun. 15, 1466 (2024).
Article ADS CAS PubMed PubMed Central Google Scholar
Desiatov, B., Shams-Ansari, A., Zhang, M., Wang, C. & Lončar, M. Ultra-low-loss integrated visible photonics using thin-film lithium niobate. Optica 6, 380–384 (2019).
Article ADS CAS Google Scholar
Honardoost, A., Abdelsalam, K. & Fathpour, S. Rejuvenating a versatile photonic material: thin-film lithium niobate. Laser Photon. Rev. 14, 2000088 (2020).
Article ADS CAS Google Scholar
Qi, Y. & Li, Y. Integrated lithium niobate photonics. Nanophotonics 9, 1287–1320 (2020).
Article CAS Google Scholar
Zhu, D. et al. Integrated photonics on thin-film lithium niobate. Adv. Opt. Photon. 13, 242–352 (2021).
Article Google Scholar
Churaev, M. et al. A heterogeneously integrated lithium niobate-on-silicon nitride photonic platform. Nat. Commun. 14, 3499 (2022).
Brès, Camille-Sophie et al. Supercontinuum in integrated photonics: generation, applications, challenges, and perspectives. Nanophotonics 12, 1199–1244 (2023).
Article PubMed PubMed Central Google Scholar
Wang, C. et al. Ultrahigh-efficiency wavelength conversion in nanophotonic periodically poled lithium niobate waveguides. Optica 5, 1438–1441 (2018).
Article ADS CAS Google Scholar
Chen, Jia-yang et al. Efficient parametric frequency conversion in lithium niobate nanophotonic chips. OSA Contin. 2, 2914–2924 (2019).
Article CAS Google Scholar
Yu, M., Desiatov, B., Okawachi, Y., Gaeta, A. L. & Lončar, M. Coherent two-octave-spanning supercontinuum generation in lithium-niobate waveguides. Opt. Lett. 44, 1222–1225 (2019).
Article ADS CAS PubMed Google Scholar
Lu, J., Surya, J. B., Liu, X., Xu, Y. & Tang, H. X. Octave-spanning supercontinuum generation in nanoscale lithium niobate waveguides. Opt. Lett. 44, 1492–1495 (2019).
Article ADS CAS PubMed Google Scholar
Jankowski, M. et al. Ultrabroadband nonlinear optics in nanophotonic periodically poled lithium niobate waveguides. Optica 7, 40–46 (2020).
Article ADS CAS Google Scholar
Reig Escalé, M., Kaufmann, F., Jiang, H., Pohl, D. & Grange, R. Generation of 280 THz-spanning near-ultraviolet light in lithium niobate-on-insulator waveguides with sub-100 pJ pulses. APL Photonics 5, 121301 (2020).
Article ADS Google Scholar
Okawachi, Y. et al. Chip-based self-referencing using integrated lithium niobate waveguides. Optica 7, 702–707 (2020).
Article ADS CAS Google Scholar
Sayem, AyedAl et al. Efficient and tunable blue light generation using lithium niobate nonlinear photonics. Appl. Phys. Lett. 119, 231104 (2021).
Article ADS CAS Google Scholar
Obrzud, E. et al. Stable and compact RF-to-optical link using lithium niobate on insulator waveguides. APL Photonics 6, 121303 (2021).
Article ADS CAS Google Scholar
Park, T. et al. High-efficiency second harmonic generation of blue light on thin-film lithium niobate. Opt. Lett. 47, 2706–2709 (2022).
Article ADS CAS PubMed Google Scholar
Wu, T.-H. et al. Visible-to-ultraviolet frequency comb generation in lithium niobate nanophotonic waveguides. Nat. Photonics 18, 218–223 (2024).
Perruchot, S. et al. The SOPHIE spectrograph: design and technical key-points for high throughput and high stability. In Ground-Based and Airborne Instrumentation for Astronomy II 235–246. (SPIE, 2008).
Okubo, S., Onae, A., Nakamura, K., Udem, T. & Inaba, H. Offset-free optical frequency comb self-referencing with an f-2f interferometer. Optica 5, 188–192 (2018).
Article ADS CAS Google Scholar
Obrzud, E. et al. Broadband near-infrared astronomical spectrometer calibration and on-sky validation with an electro-optic laser frequency comb. Opt. Express 26, 34830–34841 (2018).
Article ADS CAS PubMed Google Scholar
Beha, K. et al. Electronic synthesis of light. Optica 4, 406–411 (2017).
Article ADS CAS Google Scholar
Voumard, T. et al. Simulating supercontinua from mixed and cascaded nonlinearities. APL Photonics 8, 036114 (2023).
Article ADS Google Scholar
Suhara, T. & Nishihara, H. Theoretical analysis of waveguide second-harmonic generation phase matched with uniform and chirped gratings. IEEE J. Quantum Electron. 26, 1265–1276 (1990).
Article ADS CAS Google Scholar
Wildi, F., Pepe, F., Chazelas, B., Curto, G. L. & Lovis, C. A Fabry-Perot calibrator of the HARPS radial velocity spectrograph: performance report. In Ground-Based and Airborne Instrumentation for Astronomy III 1853–1863. (SPIE, 2010).
Wildi, F., Chazelas, B. & Pepe, F. A passive cost-effective solution for the high accuracy wavelength calibration of radial velocity spectrographs. In Ground-Based and Airborne Instrumentation for Astronomy IV 1122–1129. (SPIE, 2012).
Bouchy, F. et al. SOPHIE+: first results of an octagonal-section fiber for high-precision radial velocity measurements. Astronom. Astrophys. 549, A49 (2013).
Article Google Scholar
Schmidt, T. M. et al. Fundamental physics with ESPRESSO: towards an accurate wavelength calibration for a precision test of the fine-structure constant. Astronom. Astrophys. 646, A144 (2021).
Article Google Scholar
Zechmeister, M., Anglada-Escudé, G. & Reiners, A. Flat-relative optimal extraction - A quick and efficient algorithm for stabilised spectrographs. Astronom. Astrophys. 561, A59 (2014).
Article ADS Google Scholar
Cersullo, F., Coffinet, A., Chazelas, B., Lovis, C. & Pepe, F. New wavelength calibration for echelle spectrographs using Fabry-Pérot etalons. Astronom. Astrophys. 624, A122 (2019).
Article ADS CAS Google Scholar
Bouchy, F., Pepe, F. & Queloz, D. Fundamental photon noise limit to radial velocity measurements. Astronom. Astrophys. 374, 733–739 (2001).
Article ADS Google Scholar
Coffinet, A., Lovis, C., Dumusque, X. & Pepe, F. New wavelength calibration of the HARPS spectrograph. Astronom. Astrophys. 629, A27 (2019).
Article ADS CAS Google Scholar
Bouchy, F. et al. Charge transfer inefficiency effect for high-precision radial velocity measurements. EAS Publ. Ser. 37, 247–253 (2009).
Article Google Scholar
Redman, S. L., Nave, G. & Sansonetti, C. J. The spectrum of thorium from 250 nm to 5500 nm: Ritz wavelengths and optimized energy levels. Astrophys. J. Suppl. Ser. 211, 4 (2014).
Article ADS Google Scholar
Helgason, Ó. B. et al. Surpassing the nonlinear conversion efficiency of soliton microcombs. Nat. Photon. 17, 992–999 (2023).
Herr, T. et al. Temporal solitons in optical microresonators. Nat. Photonics 8, 145–152 (2014).
Article ADS CAS Google Scholar
Herr, S. J. et al. Frequency comb up- and down-conversion in synchronously driven χ(2) optical microresonators. Opt. Lett. 43, 5745–5748 (2018).
Article ADS CAS PubMed Google Scholar
Jankowski, M., Mishra, J. & Fejer, M. M. Dispersion-engineered nanophotonics: a flexible tool for nonclassical light. J. Phys. Photonics 3, 042005 (2021).
Article ADS CAS Google Scholar
Roy, A. et al. Visible-to-mid-IR tunable frequency comb in nanophotonics. Nat. Commun. 14, 6549 (2023).
Article ADS CAS PubMed PubMed Central Google Scholar
Ye, Z., Twayana, K., Andrekson, P. A. & Torres-Company, V. High-Q Si3N4 microresonators based on a subtractive processing for Kerr nonlinear optics. Opt. Express 27, 35719–35727 (2019).
Article ADS CAS PubMed Google Scholar
Ye, Z. et al. Integrated, ultra-compact high-Q silicon nitride microresonators for low-repetition-rate soliton microcombs. Laser Photon. Rev. 16, 2100147 (2022).
Article ADS CAS Google Scholar
Liu, F. et al. High resistance against ultraviolet photorefraction in zirconium-doped lithium niobate crystals. Opt. Lett. 35, 10–12 (2010).
Article ADS CAS PubMed Google Scholar
He, L. et al. Low-loss fiber-to-chip interface for lithium niobate photonic integrated circuits. Opt. Lett. 44, 2314–2317 (2019).
Article ADS CAS PubMed Google Scholar
Liu, X. et al. Beyond 100 THz-spanning ultraviolet frequency combs in a non-centrosymmetric crystalline waveguide. Nat. Commun. 10, 2971 (2019).
Article ADS PubMed PubMed Central Google Scholar
Probst, R. A. et al. A laser frequency comb featuring sub-cm/s precision for routine operation on HARPS. In Ground-Based and Airborne Instrumentation for Astronomy V 498–509. (SPIE, 2014).
Younesi, M. et al. Periodic poling with a micrometer-range period in thin-film lithium niobate on insulator. J. Opt. Soc. Am. B 38, 685–691.
Newman, Z. L. et al. High-performance, compact optical standard. Opt. Lett. 46, 4702–4705 (2021).
Aghanim, N. et al. Planck 2018 results - VI. Cosmological parameters. Astronom. Astrophys. 641, A6 (2020).
Article Google Scholar
Download references
This project has received funding from the Swiss National Science Foundation (Sinergia BLUVES CRSII5_193689 (F.B., D.G., and T.H.)), the European Research Council (ERC) under the EU’s Horizon 2020 research and innovation program (ERC StG 853564 (T.H.) and ERC CoG 771410 (V.T.-C.)), and through the Helmholtz Young Investigators Group VH-NG-1404 (T.H.); the work was supported through the Maxwell computational resources operated at DESY. The lithium niobate waveguides were fabricated in the EPFL Center of MicroNanoTechnology (CMi).
Open Access funding enabled and organized by Projekt DEAL.
These authors contributed equally: Markus Ludwig, Furkan Ayhan, Tobias M. Schmidt.
Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607, Hamburg, Germany
Markus Ludwig, Thibault Wildi, Thibault Voumard, Mahmoud A. Gaafar & Tobias Herr
École Polytechnique Fédérale de Lausanne (EPFL), 1015, Lausanne, Switzerland
Furkan Ayhan & Luis G. Villanueva
Observatoire de Genève, Département d’Astronomie, Université de Genève, Chemin Pegasi 51b, 1290, Versoix, Switzerland
Tobias M. Schmidt, François Wildi, Francesco Pepe, Bruno Chazelas & François Bouchy
Swiss Center for Electronics and Microtechnology (CSEM), 2000, Neuchâtel, Switzerland
Roman Blum, Ewelina Obrzud, Davide Grassani, Olivia Hefti, Sylvain Karlen & Steve Lecomte
Department of Microtechnology and Nanoscience, Chalmers University of Technology, 41296, Gothenburg, Sweden
Zhichao Ye, Fuchuan Lei & Victor Torres-Company
Observatoire de Haute-Provence, CNRS, Université d’Aix-Marseille, 04870, Saint-Michel-l’Observatoire, France
François Moreau & Rico Sottile
Q.ANT GmbH, Handwerkstraße 29, 70565, Stuttgart, Germany
Victor Brasch
Physics Department, Universität Hamburg UHH, Luruper Chaussee 149, 22607, Hamburg, Germany
Tobias Herr
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
M.L. built the setup for ultrahigh repetition rate pulse amplification and compression, designed, and tested the waveguides, F.A. developed the waveguide fabrication and poling process and fabricated the waveguides, T.S. developed analysis software and analyzed the calibration data, T.W. operated the microresonator comb and built the EOM setup, T.V. supported laser stabilization, R.B. designed, built, and operated the stabilized CW laser, Z.Y., F.L., and V.T.-C. designed and fabricated the microresonator, M.L., F.A., T.S., T.W., T.V., R.B., V.B., F.B., and T.H. performed the calibration experiments, F.W., F.P., M.A.G., E.O., D.G., S.K., S.L., F.M., B.C., and R.S. supported the experiments, O.H. performed the UV damage study, V.B., L.G.V., F.B., and T.H. conceived and supervised the project. M.L., F.A., T.M.S., and T.H. wrote the manuscript with input from all authors.
Correspondence to Tobias Herr.
The authors declare no competing interests.
Nature Communications thanks the anonymous reviewers for their contribution to the peer review of this work. A peer review file is available.
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Reprints and permissions
Ludwig, M., Ayhan, F., Schmidt, T.M. et al. Ultraviolet astronomical spectrograph calibration with laser frequency combs from nanophotonic lithium niobate waveguides. Nat Commun 15, 7614 (2024). https://doi.org/10.1038/s41467-024-51560-x
Download citation
Received: 28 August 2023
Accepted: 12 August 2024
Published: 02 September 2024
DOI: https://doi.org/10.1038/s41467-024-51560-x
Anyone you share the following link with will be able to read this content:
Sorry, a shareable link is not currently available for this article.
Provided by the Springer Nature SharedIt content-sharing initiative
Nature Communications (2024)